http://WWW.MNRELECTRICALS.IN
MNRELECTRICALS 5aa90ca4cf42970afc825261 False 33 1
OK
background image not found
Found Update results for
'fault level'
5
Top Features of Our Bus ducts: Bus duct with a required rating, Fault level. Designing of Bus Duct to achieve required Fault Level, considering temp. Rise, Thermal Rating, Stress, withstand capacity and all applicable dating factors. Bus Duct up to 4000A with Copper/Aluminum Busbar Bus bar supported by DMC/SMC Support Bus bar with Heat Shrinkable Sleeve. Indoor/Outdoor Duty, the Separate adapter at both ends with Space heater & earth bus. Air insulated, Non-segregated type. Short circuit rating of 50KA for 1sec RMS Also non-magnetic aluminum enclosures Flexible terminations Flexible In-line Connections
The rising mains rise from the intake power source like substation or switch board to the upper level of the structure. Typically they will be either cables which feed switchboards/distribution panels on each level, or encapsulated bus-bar systems which have access covers to tap into where needed. We are the top & best manufacturers and suppliers of rising mains in Hyderabad, Bangalore, Delhi, Karnataka, Mumbai, and Maharashtra.
Top Features of Our Synchronization panels Load Manager, Power reverse protection Earth fault, filed lost control, auto manual synchronization, dual voltmeter, dual frequency meter, all come in a single panel. Automatic start and stop of the generator and changeover the EB/generator lines Auto/manual selector is available Genset stop with a delay of 3 min Hooter-alarm annunciation for fail to start Checklist to find the fault and to correct 4ST switch control for a healthy start and stop of Genset Manual start & stop switch Available with emergency stop switch Auto LLOP (Low Lube Oil Pressure) and (High Water Temperature) protections are available (LLOT & HWT Sensors-Relays are not part of this panel\provided with control wires and safety according to their generators standard.
Best Features Of AMF Control Panels: Generator starting, stopping and monitoring sequence Automatic shutdown during any DG fault. Configurable via front panel feather touch push buttons. Configurable Solid state Outputs. Large number of configurable timers. Continuous monitoring of three-phase voltage/current/frequency of mains and DG along with battery voltage of DG
Advanced Earthing Electrodes: Robust design to last for a lifetime Three level protection from corrosion OUTER Pipe (GI/Copper) A layer of superconductive crystalline compound Primary conductor (Pipe/Strip)
1
false