Top Features of Our Bus ducts: Bus duct with a required rating, Fault level. Designing of Bus Duct to achieve required Fault Level, considering temp. Rise, Thermal Rating, Stress, withstand capacity and all applicable dating factors. Bus Duct up to 4000A with Copper/Aluminum Busbar Bus bar supported by DMC/SMC Support Bus bar with Heat Shrinkable Sleeve. Indoor/Outdoor Duty, the Separate adapter at both ends with Space heater & earth bus. Air insulated, Non-segregated type. Short circuit rating of 50KA for 1sec RMS Also non-magnetic aluminum enclosures Flexible terminations Flexible In-line Connections
2018-07-21T05:09:35
update image not found
Best Features Of AMF Control Panels: Generator starting, stopping and monitoring sequence Automatic shutdown during any DG fault. Configurable via front panel feather touch push buttons. Configurable Solid state Outputs. Large number of configurable timers. Continuous monitoring of three-phase voltage/current/frequency of mains and DG along with battery voltage of DG
2018-07-18T12:28:03
update image not found
Top Features of PPC Panel: Designed to meet the requirement of IS-8623 on Factory build assemblies Bus bar rating up to 4000A Short circuit withstand capacity of 50kA for 1 sec RMS Totally enclosed, Cubicle type compartmentalized construction Free standing, Floor mounting Extendable on both sides Cable entry from Top & Bottom Customer choice of switchgear DMC/SMC reinforced FRP material for bus bars support. Front and Rear access Single / Double Bus bar system Auto source changeover PLC logic for Source changeover Distribution Panels suitable for installations
2018-07-13T12:30:48
update image not found
Top Features of Our Synchronization panels Load Manager, Power reverse protection Earth fault, filed lost control, auto manual synchronization, dual voltmeter, dual frequency meter, all come in a single panel. Automatic start and stop of the generator and changeover the EB/generator lines Auto/manual selector is available Genset stop with a delay of 3 min Hooter-alarm annunciation for fail to start Checklist to find the fault and to correct 4ST switch control for a healthy start and stop of Genset Manual start & stop switch Available with emergency stop switch Auto LLOP (Low Lube Oil Pressure) and (High Water Temperature) protections are available (LLOT & HWT Sensors-Relays are not part of this panel\provided with control wires and safety according to their generators standard.
2018-07-10T10:13:39
update image not found
An open grid assembly of metal bars, in which the bearing bars, running in one direction, are spaced by rigid attachment to cross bars running perpendicular to them or by bent connection bars extending between them.